| Item |
Specification |
| Cabinet installation standards |
Can be installed in an 1000 mm-deep standard 19-inch cabinet and is installed in a 2200 mm-high HW N610E cabinet by default. |
| Dimensions without packaging (H x W x D) [mm(in.)] |
1016 mm x 442 mm x 945 mm (40 in. x 17.4 in. x 37.2 in.) |
| Dimensions with packaging (H x W x D) [mm(in.)] |
1016 mm x 442 mm x 945 mm (40 in. x 17.4 in. x 37.2 in.) |
| Chassis height [U] |
23 U |
| Weight without packaging [kg(lb)] |
181 kg (399.0 lb) |
| Weight without packaging (full configuration) [kg(lb)] |
374kg (824.5 lb) |
| Typical power consumption (with configuration) [W] |
- Typical 7970W (include 8 PMs, 3 LPU FANs, 2 SFU FANs) 2 MPU + 8 SFU + 8 20x100G QSFP28
- Typical 13500W (include 9 PMs, 3 LPU FANs, 2 SFU FANs) 2 MPU + 8 SFU + 8 40x100G QSFP28
- Typical 9079W (include 8 PMs, 3 LPU FANs, 2 SFU FANs) 2 MPU + 8 SFU + 20 20x100G QSFP28 (03058864)
|
| Typical heat dissipation (with configuration) [BTU/hour] |
- 25858 BTU/hour (include 8 PMs, 3 LPU FANs, 2 SFU FANs) 2 MPU + 8 SFU + 8 20x100G QSFP28
- 43799.7 BTU/hour (include 9 PMs, 3 LPU FANs, 2 SFU FANs) 2 MPU + 8 SFU + 8 40x100G QSFP28
- 29456.1 BTU/hour (include 8 PMs, 3 LPU FANs, 2 SFU FANs) 2 MPU + 8 SFU + 20 20x100G QSFP28 (03058864)
|
| MTBF [year] |
18.87 year |
| MTTR [hour] |
0.5 hour |
| Availability |
0.99999 |
| Power supply mode |
DC built-in |
| Maximum number of power chassis inputs |
(8 channels/PEM)*3 PEM=(2 channels/PM)*4 PM*3 PEM=24 channels |
| Rated input voltage [V] |
-48 V / -60 V |
| Input voltage range [V] |
-40 V to -72 V |
| Maximum input current [A] |
63 A/single-module |
| Maximum input cable size [mm²] |
35 mm²/channel |
| Front-end circuit breaker/fuse [A] |
2 channels of 63 A/single-module [4T bundle] DC device: 6 PMs, with a total of 12 channels of 63 A |
| Noise at normal temperature (acoustic power) [dB(A)] |
77.2dBA, NEBS-compliance (< 78 dBA @ 27°C) |
| Number of slots |
18 |
| Number of service board slots |
8 |
| Switching capacity |
83.78 Tbit/s |
| Redundant MPUs |
1:01 |
| Redundant Switch fabrics |
7+1 |
| Redundant CMUs |
1:01 |
| Redundant power supply |
[4T bundle] 5+1 |
| Redundant fans |
The device has two fan partitions. The LPU partition has three fan assemblies, which support 2+1 fan assembly redundancy. The SFU partition has two fan assemblies, which support 1+1 fan assembly redundancy. |
| Long-term operating temperature [°C(°F)] |
0 °C ~ 40°C(32 °F ~ 104.0°F) |
| Short-term operating temperature [°C(°F)] |
-5 °C ~ 50°C (23 °F ~ 122.0°F) |
| Storage temperature [°C(°F)] |
-40 °C ~ 70 °C (-40.0°F ~ 158.0°F) |
| Long-term operating relative humidity [RH] |
5% to 85%, non-condensing |
| Short-term operating relative humidity [RH] |
5% to 95% RH, non-condensing |
| Storage relative humidity [RH] |
5% to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] |
≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].) |
| Storage altitude [m(ft.)] |
< 5000 m (16404.2 ft.) |